Every Pixel Is an Option: A System One Model for Medical Ultrasound Biometry

✨ arXiv preprint, 2026 ✨

Moein Heidari, Junbo Rao, Yudan Chen, Yasamin Medghalchi, River Jiang, Wenjin Chen, David J. Foran, Jasmine Grewal, Ilker Hacihaliloglu
Overview of Kev-Bio. Qwen3.5 and USFM provide visual tokens to the language model, while DINOv2 contributes additional l
Figure 1. Overview of Kev-Bio. Qwen3.5 and USFM provide visual tokens to the language model, while DINOv2 contributes additional localization features. Clinical questions are encoded into decision states at decide tokens, which generate queries for each landmark endpoint. A convolutional-based Pixel Neck combines features from the three visual encoders into a shared dense feature map. Endpoint queries are matched against this map to produce spatial probability maps, from which landmark coordinates and clinical measurements are derived.

Abstract

Purpose: Ultrasound biometry is widely used across various clinical applications, including prenatal and cardiac examinations, to obtain quantitative measurements by placing calipers at anatomical landmarks. However, these measurements remain subject to interoperator variability as they rely largely on manual caliper placement. Conventional methods often use specialized prediction heads for different ultrasound tasks, whereas vision-language models offer flexibility through text instructions. However, direct coordinate prediction does not explicitly model spatial likelihood distributions, limiting the representation of localization ambiguity. Methods: We propose Kev-Bio, a vision-language model that uses clinical measurement questions to guide ultrasound landmark detection. Inspired by System One decision models, Kev-Bio uses decision representations of the language model to generate queries for each caliper endpoint. These queries are matched against shared dense ultrasound features to produce spatial probability maps, from which landmark coordinates and clinical measurements are derived. The model is trained end-to-end using both landmark localization and clinical measurement losses. Results: On the nine-view FU/GU Biometry 2026 dataset, Kev-Bio achieves a mean radial error (MRE) of 22.50 pixels and a clinical measurement mean absolute error (MAE) of 15.38, outperforming the compared baselines in overall performance. Conclusion: These results demonstrate the effectiveness of Kev-Bio for ultrasound landmark detection and clinical measurement across different anatomical views. Our code and models are available at https://github.com/moeinheidari7829/Kev-Bio.

Results

Table 1. FU/GU Biometry 2026 labelled dataset. Samples: number of labelled images; LM: landmarks per image; Meas.: clinical measurements per image (D: distance, C: ellipse circumference, A: angle).
TaskViewSamplesLMMeas.
Cardiac
A4CApical four-chamber108168 D
PLAXParasternal long-axis872211 D
PSAXParasternal short-axis4942 D
IVCSubcostal inferior vena cava3821 D
Prenatal
HCFetal head (transthalamic)99941 D + 1 C
FAFetal abdomen50041 C
FemurFetal femur70221 D
FUGCTransvaginal cervix26021 D
Intrapartum
AoPTransperineal (angle of progression)4,00041 D + 1 A
Total9 views6,7436029
Table 2. Comparison on 5-fold cross-validation of the FU/GU Biometry 2026 training set (lower is better). Top: mean radial error of landmarks (MRE, px). Bottom: mean absolute error of clinical measurements (MAE; px, degrees for AoP). Per-task values are averaged over five folds; Avg. is the macro mean over nine tasks ± s.d. over folds. Params: total trainable parameters in millions. Best and second best per column among reported values.
MethodParams (M)CardiacPrenatalIntrapartumAvg.
A4CPLAXPSAXIVCHCFAFemurFUGCAoP
MRE (px) ↓
General Baselines
nnLandmark Ertl et al. (2026)140.144.2326.7158.8745.9225.4519.3622.286.998.7928.73 ± 4.12
MedSapiens Elbatel et al. (2026)24.0118.8576.49108.41130.0935.3224.3424.7511.569.6159.94 ± 4.15
Challenge Baselines
CAMS Li et al. (2026)35.544.9220.9942.7636.3118.0717.0419.296.868.7123.88 ± 2.10
IMPACT-L Rasaee and Rivaz (2026)144.444.4023.3260.2251.7217.0315.9519.667.549.4127.70 ± 3.18
FMUB Wu et al. (2026)29.541.7321.4548.8041.1718.5816.5820.396.909.2224.98 ± 3.41
US-Foundation Panagiotakopoulou et al. (2026)56.144.6922.1551.3345.1017.7016.4820.166.618.4425.85 ± 2.87
Kev-Bio (ours)35.040.8820.9542.2435.0813.7615.8618.776.478.4822.50 ± 2.10
MAE ↓
General Baselines
nnLandmark Ertl et al. (2026)25.6512.3135.3122.4323.4753.9618.854.464.8522.37 ± 1.47
MedSapiens Elbatel et al. (2026)59.7740.2775.64105.4327.1671.6819.877.505.3445.85 ± 4.15
Challenge Baselines
CAMS Li et al. (2026)24.958.5222.459.9024.0952.0515.634.325.3318.58 ± 1.28
IMPACT-L Rasaee and Rivaz (2026)18.829.3736.0811.1815.8050.9416.495.385.7018.86 ± 1.20
FMUB Wu et al. (2026)18.008.7425.1011.1215.0052.2317.454.225.3417.47 ± 0.90
US-Foundation Panagiotakopoulou et al. (2026)22.4210.5428.7715.8714.9351.7217.943.924.6318.97 ± 1.41
Kev-Bio (ours)16.128.4219.239.4810.5949.2216.534.004.8415.38 ± 1.24
Qualitative comparison across nine ultrasound views. Landmark predictions from Kev-Bio (red) and US-Foundation (blue), w
Figure 2. Qualitative comparison across nine ultrasound views. Landmark predictions from Kev-Bio (red) and US-Foundation (blue), with ground truth shown in green. Values indicate mean landmark error in pixels.
Spatial probability maps and error detection. (a) Landmark probability maps showing confident and ambiguous predictions.
Figure 3. Spatial probability maps and error detection. (a) Landmark probability maps showing confident and ambiguous predictions. (b) Landmarks are ranked by decreasing map entropy, and curves show the fraction of localization errors captured in each clinical domain. Errors are defined using ground truth as deviations exceeding 5% of the image diagonal. The black marker indicates the overall result, and the dashed line represents random selection.
Question-conditioned landmark localization. Different clinical measurement questions produce distinct landmark probabili
Figure 4. Question-conditioned landmark localization. Different clinical measurement questions produce distinct landmark probability maps on the same ultrasound image. Green circles denote ground truth, and yellow regions indicate predicted spatial distributions.
Table 3. Component ablation of Kev-Bio. We assess the impact of DINOv2, LLM-guided queries, and pointer-based localization. Results are the mean ± s.d. over five folds. Lower is better.
VariantDINOv2LLMPointerMRE (px) ↓MAE ↓
w/o DINOv2✗✓✓24.85 ± 2.6616.94 ± 0.94
w/o LLM✓✗✓23.66 ± 2.6316.77 ± 1.23
w/o pixel pointer✓✓✗35.50 ± 3.1223.64 ± 1.60
Kev-Bio (full)✓✓✓22.50 ± 2.1015.38 ± 1.24

BibTeX

@article{heidari2026every,
  title   = {Every Pixel Is an Option: A System One Model for Medical Ultrasound Biometry},
  author  = {Heidari, Moein and Rao, Junbo and Chen, Yudan and Medghalchi, Yasamin and Jiang, River and Chen, Wenjin and Foran, David J. and Grewal, Jasmine and Hacihaliloglu, Ilker},
  journal = {arXiv preprint arXiv:2611.03360},
  year    = {2026}
}