Echo-CoPilot: A Multiple-Perspective Agentic Framework for Reliable Echocardiography Interpretation

✨ MICCAI 2026 Agentic AI for Medicine Workshop ✨

Moein Heidari, Ali Mehrabian, Mohammad Amin Roohi, River Jiang, Wenjin Chen, David J. Foran, Jasmine Grewal, Ilker Hacihaliloglu
Overview of Echo-CoPilot. Panel (a) shows the three perspective ReAct-style agents and the contrast module. Panel (b) il
Figure 1. Overview of Echo-CoPilot. Panel (a) shows the three perspective ReAct-style agents and the contrast module. Panel (b) illustrates EchoKG measurement selection/avoidance and threshold-based grading of ventricular dilation severity.

Abstract

Echocardiography interpretation requires integrating multi-view temporal evidence with quantitative measurements and guideline-grounded reasoning, yet existing foundation-model pipelines largely solve isolated subtasks and fail when tool outputs are noisy or values fall near clinical cutoffs. We propose Echo-CoPilot, an end-to-end agentic framework that combines a multi-perspective workflow with knowledge-graph-guided measurement selection. Echo-CoPilot runs three independent ReAct-style agents, structural, pathological, and quantitative, that invoke specialized echocardiography tools to extract parameters while querying EchoKG to determine which measurements are required for the clinical question and which should be avoided. A self-contrast language model then compares the evidence-grounded perspectives, generates a discrepancy checklist, and re-queries EchoKG to apply the appropriate guideline thresholds and resolve conflicts, reducing hallucinated measurement selection and borderline flip-flops. On MIMICEchoQA, Echo-CoPilot provides higher accuracy compared to SOTA baselines and, under a stochasticity stress test, achieves higher reliability through more consistent conclusions and fewer answer changes across repeated runs. Our code is publicly available at https://github.com/moeinheidari7829/Echo-CoPilot.

Experiments

Table 1. Accuracy (Acc.) of general-purpose and biomed-specialized VLMs on the MIMICEchoQA benchmark. Models marked with * are taken directly from OpenBiomedVid [16, 17].
ModelAcc.ModelAcc.
Video-ChatGPT*31.7Video-LLaVA*32.0
Phi-3.5-Vision-Instruct*41.1Phi-4-Multimodal-Instruct*37.8
InternVideo2.5-Chat-8B*40.3Qwen2-VL-7B-Instruct*37.9
Qwen2.5-VL-7B-Instruct*34.0Qwen2 VL 72B Instruct*37.5
Qwen2.5-VL-72B-Instruct*34.2Gemini-2.0-Flash*38.4
GPT-4o*41.6GPT-o4-mini*43.9
Qwen2-VL-2B-Biomed*42.0Qwen2-VL-7B-Biomed*49.0
MedGemma-4B33.4LLaVA-Med32.5
Echo-CoPilot54.0 ± 0.7
Table 2. Stability Comparison across Testing Modes: consistency over 10 runs for N=50 questions. Best results are in bold.
MetricLLMLLM+ToolsReAct AgentEcho-CoPilot
Stability Rate ↑40.0%26.0%70.0%72.0%
Avg Unique Answers ↓1.862.001.301.22
Avg Changes ↓2.102.581.140.96
Table 3. Left: Error concentration on three frequent failure groups, comparing Qwen2-VL-7B-Biomed [17] with Echo-CoPilot. Right: Ablation study on each component of Echo-CoPilot: EchoKG, ReAct loop, and self-contrast (SC) mechanism. Best results are in bold.
Error Analysis (err.%)Ablation Study
GroupQwenOursVariantToolsEchoKGReActSCAcc.
Doppler views83.059.3LLM°°°°46.9
PSAX vessels71.059.6LLM+Tools••°°49.7
Left atrium68.460.5ReAct Agent•••°52.3
Echo-CoPilot••••54.0

BibTeX

@article{heidari2025echocopilot,
  title   = {Echo-CoPilot: A Multiple-Perspective Agentic Framework for Reliable Echocardiography Interpretation},
  author  = {Heidari, Moein and Mehrabian, Ali and Roohi, Mohammad Amin and Jiang, River and Chen, Wenjin and Foran, David J. and Grewal, Jasmine and Hacihaliloglu, Ilker},
  journal = {arXiv preprint arXiv:2512.09944},
  year    = {2025}
}